2 vector control, Vector control, Commissioning – Lenze E82xVxxxKxxxxx User Manual
Page 206
![background image](/manuals/566070/206/background.png)
Commissioning
Parameter setting with E82ZBC keypad
Vector control
l
206
EDS82EV903 EN 3.0
Comment
Switch−on sequence
When all settings are complete:
15.
Select setpoint
E.g. via potentiometer at
terminals 7, 8, 9
16.
Enable the controller
20
28
X3
misc002
Terminal X3/28 = HIGH
17.
The drive is now running.
If the drive does not start,
additionally press
u
8.3.2
Vector control
The following instructions apply to controllers equipped with a standard−I/O function
module and a three−phase AC motor which has been selected according to a power−based
assignment.
Switch−on sequence
Comment
1.
Connect keypad
2.
Ensure that controller inhibit is active after
mains connection
misc001
20
28
X3
}
Terminal X3/28 = LOW
3.
Switch on the mains
ON
misc002
4.
The keypad is in "Disp" mode after approx. 2 s
and indicates the output frequency (C0050)
000
000
a
b
c
d
e
m n o
p
q r
Hi
Hz
Lo
1
j g f k i h PS
0050
The USEr menu is active
5.
Go to the ALL menu
6.
Change to the
f mode to configure the basic
settings for your drive
000
000
a
b
c
d
e
m n o
p
q r
Hi
Hz
Lo
1
j g f k i h PS
0050
z
y
w x
Blinking on the display: 0050
7.
Adapt the terminal configuration to the wiring
(C0007)
Lenze setting: −0−, i. e.
E1: JOG1/3 fixed setpointselection
E2: JOG2/3
E3: DCB DC brake
E4: CW/CCW rotation
z
y
w x
0
000
a
b
c
d
e
m n o
p
q r
Hi
Lo
1
j g f k i h PS
0007
8.
Set the minimum output frequency (C0010)
Lenze setting: 0.00 Hz
0 %
[f]
100 %
C0011
C0010
9.
Set the maximum output frequency (C0011)
Lenze setting: 50.00 Hz
10.
Set the acceleration time T
ir
(C0012)
Lenze setting: 5.00 s
f [ H z ]
f 2
C 0 0 1 1
f 1
0
t i r
t i f
T i r
T i f
t
T
ir
+ t
ir
@
C0011
f2 * f1
t
ir
= desired acceleration time
11.
Set the deceleration time T
if
(C0013)
Lenze setting: 5.00 s
T
if
+ t
if
@
C0011
f2 * f1
t
if
= desired deceleration time