background image

Parameter setting

Parameter setting with the XT EMZ9371BC keypad
Menu structure

9

l

246

EDS82EV903 EN 3.0

Description

Submenus

Main menu

Description

Display

No.

Display

No.

5.2

Speed−Ctrl 1

Frequency setpoint via parameter channel (C0046)
Digital actual frequency value via frequency input (DFIN)

5.2.1 Freq setpt

Frequency setpoint configuration

5.2.2 Actual value

Actual frequency value configuration

5.2.3 PCTRL setup

Process controller configuration

5.2.4 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.2.5 Motor param

Motor current control configuration, motor monitoring

5.3

Speed−Ctrl 3

Frequency setpoint via AIF process data channel (AIF−IN.W1)
Digital actual frequency value via frequency input (DFIN)

5.3.1 Freq setpt

Frequency setpoint configuration

5.3.2 Actual value

Actual frequency value configuration

5.3.3 PCTRL setup

Process controller configuration

5.3.4 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.3.5 Motor param

Motor current control configuration, motor monitoring

5.4

Speed−Ctrl 5

Operation with the system bus (CAN) function module on FIF
Frequency setpoint via process data channel (CAN−IN1.W2)
Actual frequency value via process data channel (CAN−IN1.W3)

5.4.1 CAN managem System bus (CAN) communication set−up

5.4.2 Freq setpt

Frequency setpoint configuration

5.4.3 Actual value

Actual frequency value configuration

5.4.4 PCTRL setup

Process controller configuration

5.4.5 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.4.6 Motor param

Motor current control configuration, motor monitoring

5.5

Speed−Ctrl 7

Operation with fieldbus function module on FIF (DRIVECOM
control)
Frequency setpoint via process data channel
Actual frequency value via process data channel

5.5.1 FIF managem

Fieldbus communication set−up

5.5.2 Freq setpt

Frequency setpoint configuration

5.5.3 Actual value

Actual frequency value configuration

5.5.4 PCTRL setup

Process controller configuration

5.5.5 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.5.6 Motor param

Motor current control configuration, motor monitoring

Open−loop speed control in the "V/f characteristic control" operating mode

5.6

OpenLoopV/f 0 Analog frequency setpoint via analog input 1 (AIN1)

5.6.1 Freq setpt

Frequency setpoint configuration

5.6.2 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.6.3 Motor param

Motor current control configuration, motor monitoring

5.7

OpenLoopV/f 1 Frequency setpoint via parameter channel (C0046)

5.7.1 Freq setpt

Frequency setpoint configuration

5.7.2 f limit/ramp

Output frequency, acceleration time and deceleration time
configuration

5.7.3 Motor param

Motor current control configuration, motor monitoring

Advertising