4 technical data, 1 general data and operating conditions, Technical data – Lenze E82xVxxxKxxxxx User Manual

Page 27: General data and operating conditions, 4technical data

Advertising
background image

Technical data

General data and operating conditions

4

l

27

EDS82EV903 EN 3.0

4

Technical data

4.1

General data and operating conditions

General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

2004/108/EG

EMC Directive

Approval

UL

cULus

Power Conversion Equipment (File No. E132659)

Protection of persons and equipment

Type of protection

EN 60529

IP20

IP41 in case of thermally separated installation
(push−through technique) between the control cabinet
(inside) and the environment.

NEMA 250

Protection against accidental contact in accordance with type
1

Earth leakage current

IEC/EN 61800−5−1

> 3.5 mA

Observe stipulations and safety
instructions!

Insulation of control
circuits

IEC/EN 61800−5−1

Safe mains isolation through double (reinforced) insulation

Insulation resistance

IEC/EN 61800−5−1

< 2000 m site altitude: overvoltage category III

> 2000 m site altitude: overvoltage category II

Protective measures

Against short circuit, earth fault (protected against short to
earth on power−up, limited protection against short to earth
during operation), overvoltage, motor stalling, motor
overtemperature (input for PTC thermistor or thermal
contact, I

2

t monitoring)

EMC

Noise emission

IEC/EN 61800−3

Cable−guided, category C1 or C2 when using shielded motor
cables

1)

, dependent on the device variant with integrated

interference suppression or additional RFI/mains filter

0.25 ... 11 kW

E82xVxxxKxC0xx

no additional measures

E82xVxxxKxC2xx

with external filter techniques

15 ... 90 kW

E82EVxxxK4B3xx

no additional measures

E82xVxxxK4B2xx

with external filter techniques

Noise immunity

IEC/EN 61800−3

Category C2

1)

Motor cable lengths depend on the inverter type and the switching frequency

Advertising