Function library
Code table
l
387
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0017 Frequency
threshold Q
min
0.00
0.00
{0.02
Hz}
650.00 Programmable frequency
threshold
l
Based on setpoint
l
Configure signal output in
C0415
C0018
v
Switching
frequency
2
0
2 kHz sin
General rule:
The lower the switching frequency
the
l
lower the power loss
l
higher the noise generation
Only operate mid−frequency
motors at 8 kHz sin or 16 kHz sin
(C0018 = 2 or 3)!
^ 270
1
4 kHz sin
2
8 kHz sin
low noise
generation
3
16 kHz sin
C0018
v
Switching
frequency
(only 8200 vect
or 15 ... 90 kW)
6
0
2 kHz sin
General rule:
The lower the switching frequency
the
l
lower the power loss
l
higher the noise generation
Only operate mid−frequency
motors at 8 kHz sin or 16 kHz sin
(C0018 = 2 or 3)!
^ 270
1
4 kHz sin
2
8 kHz sin
low noise
generation
3
16 kHz sin
4
2 kHz
low power loss
5
4 kHz
6
8 kHz
7
16 kHz
8
1 kHz sin
9 ... 11
Reserved
12
1 kHz
low power loss
C0019 Operating
threshold −
automatic DC
injection brake
(auto DCB)
0.10
0.00
= inactive
{0.02
Hz}
650.00 Hold time
ð C0106
Deactivate automatic DC injection
brake (auto DBC):
l
at active lower frequency
limitation (C0239)
l
at operating mode C0014 = 5
In the case of a max. output
frequency > 50 Hz (C0011), the
switching threshold of the auto
DCB in C0019 must be increased.
^ 292
C0021 Slip
compensation
0.0
−50.0
{0.1 %}
50.0 C0021 is calculated and saved
during the motor parameter
identification with C0148.
^ 268
C0022 I
max
limit in
motor mode
150
30
{1 %}
150 Only 8200 vector 15 ... 90 kW):
If C0022 = 150 %, 180 % I
rated
are
available for max. 3 s after
controller enable.
^ 284
C0023 I
max
limit in
generator
mode
150
30
{1 %}
150 C0023 = 30 %: function inactive if
C0014 = 2, 3
^ 284
C0026
*
Offset for
analog input 1
(AIN1–OFFSET)
0.0
−200.0
{0.1 %}
200.0
l
Setting for X3/8 or X3/1U,
X3/1I
l
The upper limit of the setpoint
range from C0034 corresponds
to 100 %
l
C0026 and C0413/1 are equal
^ 298
C0027
*
Gain for analog
input 1
(AIN1−GAIN)
100.0 −1500.0
{0.1 %}
1500.0
l
Setting for X3/8 or X3/1U,
X3/1I
l
100.0 % = gain 1
l
Inverted setpoint selection
through negative gain and
negative offset
l
C0027 and C0414/1 are equal
^ 298