Function library

Code table

10

l

387

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0017 Frequency

threshold Q

min

0.00

0.00

{0.02

Hz}

650.00 Programmable frequency

threshold

l

Based on setpoint

l

Configure signal output in
C0415

C0018

v

Switching
frequency

2

0

2 kHz sin

General rule:
The lower the switching frequency
the

l

lower the power loss

l

higher the noise generation

Only operate mid−frequency
motors at 8 kHz sin or 16 kHz sin
(C0018 = 2 or 3)!

^ 270

1

4 kHz sin

2

8 kHz sin

low noise
generation

3

16 kHz sin

C0018

v

Switching
frequency
(only 8200 vect
or 15 ... 90 kW)

6

0

2 kHz sin

General rule:
The lower the switching frequency
the

l

lower the power loss

l

higher the noise generation

Only operate mid−frequency
motors at 8 kHz sin or 16 kHz sin
(C0018 = 2 or 3)!

^ 270

1

4 kHz sin

2

8 kHz sin

low noise
generation

3

16 kHz sin

4

2 kHz

low power loss

5

4 kHz

6

8 kHz

7

16 kHz

8

1 kHz sin

9 ... 11

Reserved

12

1 kHz

low power loss

C0019 Operating

threshold −
automatic DC
injection brake
(auto DCB)

0.10

0.00
= inactive

{0.02

Hz}

650.00 Hold time

ð C0106

Deactivate automatic DC injection
brake (auto DBC):

l

at active lower frequency
limitation (C0239)

l

at operating mode C0014 = 5

In the case of a max. output
frequency > 50 Hz (C0011), the
switching threshold of the auto
DCB in C0019 must be increased.

^ 292

C0021 Slip

compensation

0.0

−50.0

{0.1 %}

50.0 C0021 is calculated and saved

during the motor parameter
identification with C0148.

^ 268

C0022 I

max

limit in

motor mode

150

30

{1 %}

150 Only 8200 vector 15 ... 90 kW):

If C0022 = 150 %, 180 % I

rated

are

available for max. 3 s after
controller enable.

^ 284

C0023 I

max

limit in

generator
mode

150

30

{1 %}

150 C0023 = 30 %: function inactive if

C0014 = 2, 3

^ 284

C0026
*

Offset for
analog input 1
(AIN1–OFFSET)

0.0

−200.0

{0.1 %}

200.0

l

Setting for X3/8 or X3/1U,
X3/1I

l

The upper limit of the setpoint
range from C0034 corresponds
to 100 %

l

C0026 and C0413/1 are equal

^ 298

C0027
*

Gain for analog
input 1
(AIN1−GAIN)

100.0 −1500.0

{0.1 %}

1500.0

l

Setting for X3/8 or X3/1U,
X3/1I

l

100.0 % = gain 1

l

Inverted setpoint selection
through negative gain and
negative offset

l

C0027 and C0414/1 are equal

^ 298