Function library – Lenze E82xVxxxKxxxxx User Manual
Page 394
![background image](/manuals/566070/394/background.png)
Function library
Code table
l
394
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0125
*
v
Baud rate
0
LECOM
System
bus (CAN) 217x
Only for communication modules
on the AIF interface:
l
LECOM−A (RS232) E82ZBL
l
LECOM−A/B/LI 2102
l
System bus (CAN) 217x
Set the baud rate for operation
with system bus function module
E82ZAFCC in C0351.
0
9600 baud
500 kbaud
1
4800 baud
250 kbaud
2
2400 baud
125 kbaud
3
1200 baud
50 kbaud
4
19200 baud
1000 kbaud
C0126
*
v
Behaviour with
communicatio
n error
10
Monitored communication channel
A combination of monitorings is
activated by entering the sum of
the selection values
0
All monitoring deactivated
1
Process data channel of AIF interface
Communication interrupt with
active monitoring trips TRIP CE0
2
Internal communication between
function module on FIF and drive
controller
Communication interrupt with
active monitoring trips TRIP CE5
4
Communication (Bus OFF) for
operation with function module
system bus (CAN) on FIF
Communication interrupt with
active monitoring trips TRIP CE6
8
Remote parameterisation C0370 for
operation with function module
system bus (CAN) on FIF
Communication interrupt with
active monitoring trips TRIP CE7
C0127
v
Setpoint
selection
0
0
Setpoint selection in absolute values in
Hz via C0046 or process data channel
(
±24000 º480 Hz)
1
Scaled setpoint selection via C0141 (0
... 100 %) or process data channel
(
±16384 = C0011)
C0128 Service code
Alterations by Lenze service only!