Rated data for 400 V mains voltage

Basis of the data

AC mains connection

U

r

3/PE AC 320 V − 0 % ... 440 V + 0 %; 45 Hz − 0 % ... 65 Hz + 0 %

DC−mains connection
(alternatively)

U

DC

DC 450 V − 0 % ... 620 V + 0 %

Output voltage

With mains choke

V

M

3 ~ 0 ... approx. 94 % U

mains;

0 ... 650 Hz

without mains choke

V

M

3 ~ 0 ... U

mains;

0 ... 650 Hz

Periodic load change

60 s overcurrent with I

max

and 120 s base load with 75 % I

rated

Typical motor power
Three−phase asynchronous
motor (4−pole)

P

rated

[kW]

0.75

1.1

3.0

P

rated

[hp]

1.0

1.5

4.0

8200 vector type

EMC filter integrated

E82xV551K4C0xx

E82xV751K4C0xx

2)

E82xV222K4C0xx

2)

Without EMC filter

E82xV551K4C4xx

E82xV751K4C2xx

2)

E82xV222K4C2xx

2)

Rated mains current

without mains choke

I

mains

[A]

2.9

with mains choke

I

mains

[A]

2.4

2.8

6.1

Output power +U

DC

, −U

DC

1)

P

DCres

[kW]

0.1

0

0

Rated output
current at
switching
frequency

2 kHz sin

I

r

[A]

2.2

2.9

6.7

4 kHz sin

Max. permissible
output current for
60 s at switching
frequency

2 kHz sin

I

max

[A]

2.7

3.6

8.4

4 kHz sin

Power loss (operation with
I

N24

)

E82EV...

P

loss

[W]

50

60

130

E82DV... inside/outside

P

loss

[W]

17/33

20/40

43/87

E82CV... inside/cooler

P

loss

[W]

17/33

20/40

43/87

Dimensions

Dependent on the mounting variant (

^ 61)

Mass

E82EV...

m [kg]

1.2

1.6

E82DV...

m [kg]

1.2

1.6

E82CV...

m [kg]

0.9

1.1