Mechanical installation – Lenze E82xVxxxKxxxxx User Manual

Page 96

Advertising
background image

Mechanical installation

Standard devices in the power range 75 ... 90 kW
Mounting with fixing brackets (standard)

5

l

96

EDS82EV903−3.0

Controller variant "3xx" (with fully mounted footprint filter)

For this mounting variant you require controller type E82EVxxxK4B3xx.

2

3

1

m

g

³

150 mm

a

b1

k

³

100 mm

c

d1

d2

d

b

l

e

e

f

g

a

L

M 8

max. 15 mm

c1

0

³ 50 mm

³ 50 mm

M 8

18 Nm
159.3 lb-in

8200vec283

Fig. 5−31

Standard mounting with fixing brackets 75 ... 90 kW



Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.

‚

Installation of mounting angles

ƒ

Dimensions

0

Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.

Dimensions [mm]

8200 vector

integr. mains
filter

2)

a

b

b1

c

c1

d

d1

d2

e

1)

g

k

m

E82EV553K4B3xx

E82ZN75334B230

450

802

680

393 28.5 750

38

702

375

11

28

18

E82EV553K4B3xx

E82ZN90334B230

1)

If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.

2)

The integrated mains filters are only designed for controller operation at rated power. Different filters with different
dimensions are possible (

^ 106

).

Advertising