Technical data

Open and closed loop control

4

l

30

EDS82EV903 EN 3.0

4.2

Open and closed loop control

Open and closed loop control

Open and closed loop
control modes

V/f characteristic control (linear, quadratic), vector control, torque selection

Switching frequency

0.25 ... 11 kW

2 kHz, 4 kHz, 8 kHz, 16 kHz noise optimised

15 ... 90 kW

1 kHz, 2 kHz, 4 kHz, 8 kHz, 16 kHz,
optionally noise optimised or power loss optimised

Torque behaviour

Maximum torque
0.25 ... 11 kW

1.8 x M

rated

for 60 s

if rated motor power = rated controller power

Maximum torque
15 ... 90 kW

1.8 x M

rated

for 60 s

2.1 x M

rated

for 3 s after

controller enable

Setting range

1 : 10

in speed setting range 3 ... 50 Hz, accuracy < 8 %

Torque/speed
characteristic

1.8

2.0

1.0

M/M

N

n [min ]

-1

500

1000

1500

Vector control (sensorless
speed control)

Minimum output
frequency

1.0 Hz (0 ... M

rated

)

Setting range

1 : 50

based on 50 Hz and M

rated

Accuracy

± 0.5 %

in speed setting range 3 ... 50 Hz

Smooth running

± 0.1 Hz

Output frequency

Range

− 650 Hz ... + 650 Hz

Absolute resolution

0.02 Hz

Standardised
resolution

Parameter data: 0.01 %, process data: 0.006 % (= 2

14

)

Digital setpoint selection

Accuracy

± 0.0001 %

Analog setpoint selection

Linearity

± 0.5 %

based on instantaneous value

Temperature
sensitivity

+ 0.3 % (0 ... +60 °C)

based on instantaneous value

Offset

± 0 %

A/D converter

10−bit resolution

Error: 1 digit

º 0.1 % based on final value

Operation in generator
mode

0.25 ... 11 kW

Integrated brake chopper

15 ... 90 kW

With 9352 brake chopper