Extensions for automation, Terminal data, Connection plan – Lenze E82xVxxxKxxxxx User Manual
Page 199
![background image](/manuals/566070/199/background.png)
Extensions for automation
I/O function module E82ZAFACO10 (application I/O PT)
Installation
l
199
EDS82EV903 EN 3.0
Terminal data
Field
Values
Electrical connection
2−pin plug connector with spring connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Stripping length
9 mm
Connection plan
Controller inhibit (CINH) supply via internal voltage source (X3.3/20)
9
1I 2U
1U
2I
62 63
X3.1
X3.2
+5 V
AIN2
AOUT2
AIN1
AOUT1
1U 9
7
0…+
5V
1k … 10k
A2
A1
7 A4
20 28 E1 E2 E3 E4 E5 E6
X3.3
59
GND
+20 V
DIGOUT2
DFOUT1
DIGOUT1
E82ZAFA016
Controller inhibit (CINH) supply via external voltage source
9
1I 2U
1U
2I
62 63
X3.1
X3.2
+5 V
AIN2
AOUT2
AIN1
AOUT1
1U 9
7
0
…
+5
V
1k … 10k
A2
A1
7 A4
20 28 E1 E2 E3 E4 E5 E6
X3.3
59
GND
+20 V
+
_
DIGOUT2
DFOUT1
DIGOUT1
24 V ext.
(+12 V DC - 0 % ... +30 V DC + 0 %,
max. 200 mA)
E82ZAFA015
Minimum wiring required for operation