4 setpoints via function "motor potentiometer, Setpoints via function "motor potentiometer, Function library – Lenze E82xVxxxKxxxxx User Manual

Page 307

Advertising
background image

Function library

Configuration of analog and digital setpoints and actual values

Digital setpoints via frequency input

10

l

307

EDS82EV903 EN 3.0

10.7.4

Setpoints via function "motor potentiometer"

Description

Setpoint selection via two digital signals (UP/DOWN), which are controlled by means of,
for instance, simple pushbuttons.

The output frequency in changed via the acceleration and deceleration times set for the
main setpoint (C0012/C0013) or for the additional setpoint (C0220/C0221).

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0265

v

Motor
potentiometer
configuration

3

0

Starting value = power off

l

Starting value: output
frequency which is approached
with Tir (C0012) after mains
connection when the motor
potentiometer is activated:
– "Power off" = actual value

when the power is switched
off

– "C0010": minimum output

frequency from C0010. The
setpoint must have
exceeded C0010 previously.

– "0" = output frequency of 0

Hz

l

C0265 = 3, 4, 5:
– QSP also decelerates the

motor potentiometer along
the QSP ramp (C0105)

^ 307

1

Starting value = C0010

2

Starting value = 0

3

Staring value = power off
QSP if UP/DOWN = LOW

4

Starting value = C0010
QSP if UP/DOWN = LOW

5

Starting value = 0
QSP if UP/DOWN = LOW

Activation

1. Link to external signal sources in C04110/7 UP and in C0410/8 DOWN.

)

Note!

In addition to the free configuration in C0410 you can also use the fixed
assignment in C0007 to link the function to digital inputs.

2. In C0412, assign the desired setpoint to the "Motor potentiometer" signal source

(C0412/x = 3). (

328)

Function

UP

DOWN

Run the setpoint at the QSP ramp (C0105) to 0 Hz

LOW

LOW

Run the setpoint at the main setpoint deceleration
ramp (C0013) to the minimum output frequency
(C0010)

(the setpoint must have exceeded C0010 before)

LOW

HIGH

Run the setpoint at the main setpoint acceleration
ramp (C0012) to the maximum output frequency
(C0011)

HIGH

LOW

Setpoint remains constant

HIGH

HIGH

Advertising