Mechanical installation, Cutout in the control cabinet – Lenze E82xVxxxKxxxxx User Manual

Page 65

Advertising
background image

Mechanical installation

Standard devices in a power range from 0.25 ... 2.2 kW

Thermally separated mounting (push−through technique)

5

l

65

EDS82EV903−3.0

8200 vector 1.5 ... 2.2 kW

8200vecxxx

Fig. 5−4

Dimensions for thermally separated mounting 1.5 ... 2.2 kW

1

Frame

2

Screw M4x10

3

Seal

4

Hexagon nut M4

5

Rear panel of the control cabinet

Dimensions [mm]

8200 vector

a

b

b

2

c

1

c

2

d

1

d

2

d

3

e

1)

f

1)

g

E82DV152K2C

79.4

244.5

240

4.2

71

5

80

74.5

140

100

4.5

E82DV222K2C
E82DV152K4C
E82DV222k4C

1)

If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 14 mm.

Cutout in the control cabinet

Dimensions [mm]

8200 vector

a

1

b

1

Frame

E82DV152K2C

61

221

E82ZJ00x

E82DV222K2C
E82DV152K4C
E82DV222k4C