Mechanical installation

Standard devices in a power range from 0.25 ... 2.2 kW
Lateral mounting

5

l

70

EDS82EV903−3.0

5.2.5

Lateral mounting

For this mounting variant you require the controller type E82EV...

)

Note!

This mounting variant does not enable a CE−typical drive system to be
installed.

Lateral mounting of the controller is possible on both sides. The controller is either fixed
or can be swivelled depending on the mounting point. Both mounting types use the same
mounting kit.

Fixed lateral mounting

ƒ

The fixing rails included in the scope of supply can be used for controllers 0.25 ...
0.75 kW.

ƒ

A mounting set is required for controllers 1.5 ... 2.2 kW:
– Order number E82ZJ001 for 8200 vector 1.5 ... 2.2 kW

8200vec074

Fig. 5−8

Fixed lateral mounting

 Bolt here

8200 vector

Mounting kit

Dimensions [mm]

a

b

b

1

b

2

c

1)

d

e

E82EV251K2C
E82EV371K2C

Use the fixing rails included in the scope of supply for fixed installation to

the sides. Dimensions:

^ 62

E82EV551KxC
E82EV751KxC
E82EV152KxC
E82EV222KxC

E82ZJ001

60

306

280 ... 295

240

162

6.5

39

1)

If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 14 mm.

Advertising