Extensions for automation – Lenze E82xVxxxKxxxxx User Manual
Page 200
![background image](/manuals/566070/200/background.png)
Extensions for automation
I/O function module E82ZAFACO10 (application I/O PT)
Installation
l
200
EDS82EV903 EN 3.0
X3.1/
Signal type
Function
Level
(Lenze setting: bold print)
1U/2U
Analog
inputs
Actual value or setpoint inputs (master voltage)
Change range with jumper and C0034
0 ... +5 V
0 ... +10 V
−10 V ... +10 V
1I/2I
Actual value or setpoint inputs (master current)
Change range with jumper and C0034
0 ... +20 mA
+4 ... +20 mA
+4 ... +20 mA (open−circuit
monitored)
X3.2/
Signal type
Function
Level
(Lenze setting: bold print)
62
Analog
outputs
Output frequency
Voltage output:
0 ... +6 V
0 ... +10 V
1)
Current ouput:
(0 ... +12 mA)
0 ... +20 mA
1)
+4 ... +20 mA
1)
63
Motor current
9
−
Internal, stabilised DC voltage source for setpoint
potentiometer
+5.2 V
1)
Output level 0 ... + 10 V or 0/+4 ... +20 mA: adapt offset (C0422) and gain (C0420).
X3.3/
Signal type
Function
Level
(Lenze setting: bold print)
A1
Digital
outputs
Ready for operation
0/+20 V at DC internal
0/+24 V at DC external
A2
Not preconfigured
7
−
GND, reference potential
−
A4
Frequency
output
DC−bus voltage
HIGH:
+18 V ... +24 V (HTL)
LOW: 0 V
59
−
DC supply for X3/A1 and X3/A2
+20 V (internal, bridge to X3/20)
+24 V (external)
20
−
Internal DC voltage source for control of the
digital inputs and outputs
+20 V
± 10 %
28
Digital
inputs
Controller inhibit (CINH)
1 = START
E1
1)
Activation of fixed frequencies (JOG)
JOG1 = 20 Hz
JOG2 = 30 Hz
JOG3 = 40 Hz
E1
E2
JOG1
1
0
E2
1)
JOG2
0
1
JOG3
1
1
E3
DC injection brake (DCB)
1 = DCB
E4
Reversal of rotation direction
CW rotation/CCW rotation (CW/CCW)
E4
CW
0
CCW
1
E5
Not preconfigured
−
E6
Not preconfigured
−
1)