Mechanical installation – Lenze E82xVxxxKxxxxx User Manual

Page 76

Advertising
background image

Mechanical installation

Standard devices in a power range from 3 ... 11 kW
Mounting in "cold plate" technique

5

l

76

EDS82EV903−3.0

8200 vector 3 ... 11 kW

E82CV006

Fig. 5−13

Dimensions for mounting in "cold plate" technique 3 ... 11 kW

0

Contact surface of the controller’s cooling plate to the cooler

Dimensions [mm]

8200 vector

a

a1

b

b1

b2

b3

b4

c1

c2

c3

c4

d1

d2

e

1)

g

h

E82CV302K2C

100

96

240 180

14

77

50

16

62.5

³ 3

50

20

140 106

M 4

³ 100

E82CV402K2C

E82CV552K2C

125 121

20

84.5

M 4

E82CV752K2C

10

102

M 5

E82CV302K4C

100

96

16

62.5

M 4

E82CV402K4C

E82CV552K4C

E82CV752K4C

125 121

20

84.5

M 4

E82CV113K4C

10

102

M 5

1)

If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 14 mm.

Mounting

)

Note!

ƒ

Apply the heat−conducting paste onto cooler and cooling plate before you
bolt the controller onto the cooler to reduce the heat transfer resistance to
its minimum.

ƒ

The heat−conducting paste supplied in the accessory kit will do for
approx. 1000 cm

2

.

1. Insert fixing rails into the cooling plate from above and below

2. Clean the contact surfaces of cooler and cooling plate with methylated spirit.

3. Use a spatula to apply a thin layer of heat−conducting paste.

4. Bolt the controller tightly together with the cooler using two screws.