Mechanical installation
Standard devices in a power range from 3 ... 11 kW
Mounting in "cold plate" technique
l
76
EDS82EV903−3.0
8200 vector 3 ... 11 kW
E82CV006
Fig. 5−13
Dimensions for mounting in "cold plate" technique 3 ... 11 kW
0
Contact surface of the controller’s cooling plate to the cooler
Dimensions [mm]
8200 vector
a
a1
b
b1
b2
b3
b4
c1
c2
c3
c4
d1
d2
e
1)
g
h
E82CV302K2C
100
96
240 180
14
77
50
16
62.5
³ 3
50
20
140 106
M 4
³ 100
E82CV402K2C
E82CV552K2C
125 121
20
84.5
M 4
E82CV752K2C
10
102
M 5
E82CV302K4C
100
96
16
62.5
M 4
E82CV402K4C
E82CV552K4C
E82CV752K4C
125 121
20
84.5
M 4
E82CV113K4C
10
102
M 5
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 14 mm.
Mounting
)
Note!
ƒ
Apply the heat−conducting paste onto cooler and cooling plate before you
bolt the controller onto the cooler to reduce the heat transfer resistance to
its minimum.
ƒ
The heat−conducting paste supplied in the accessory kit will do for
approx. 1000 cm
2
.
1. Insert fixing rails into the cooling plate from above and below
2. Clean the contact surfaces of cooler and cooling plate with methylated spirit.
3. Use a spatula to apply a thin layer of heat−conducting paste.
4. Bolt the controller tightly together with the cooler using two screws.