Function library – Lenze E82xVxxxKxxxxx User Manual

Page 299

Advertising
background image

Function library

Configuration of analog and digital setpoints and actual values

Analog setpoints via terminal

10

l

299

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0413

*

Offset − analog
inputs

−200.0

{0.1 %}

200.0 The upper limit of the setpoint

range from C0034 corresponds to
100 %

^ 298

1 AIN1−OFFSET

0.0

Setting for X3/8 or X3/1U, X3/1I
C0413/1 and C0026 are the same

2 AIN2−OFFSET

0.0

Setting for X3/2U, X3/2I
(only application I/O)

C0414

*

Gain − analog
inputs

−1500.0

{0.1 %}

1500.0

l

100.0 % = gain 1

l

Inverted setpoint selection
through negative gain and
negative offset

1 AIN1−GAIN

100.0

Setting for X3/8 or X3/1U, X3/1I
C0414/1 and C0027 are the same

2 AIN2−GAIN

100.0

Setting for X3/2U, X3/2I
(only application I/O)

C0430
*

v

(A)

Automatic
adjustment of
analog inputs

0

0

Inactive

The gain and offset are calculated
by entering two points of the
setpoint characteristic. Enter
points that are as far away from
each other as possible for high
accuracy of calculation:
1. In C0430, select the input the

gain and the offset are to be
calculated for

2. In C0431, enter the X value

(setpoint) and the Y value
(output frequency) of point 1

3. In C0432, enter the X value

(setpoint) and the Y value
(output frequency) of point 2

4. Calculated values are

automatically entered in C0413
(offset) and C0414 (gain)

^ 298

1

Entry of points for X3/1U, X3/1I

2

Entry of points for X3/2U, X3/2I

C0431
*

v

(A)

Coordinates of
point 1

−100.0

{0.1 %}

100.0

1 X (P1)

−100.0 Analog setpoint of P1

100 % = max. input value (5 V, 10 V or 20 mA)

2 Y (P1)

−100.0 Output frequency of P1

100 % = C0011

C0432
*

v

(A)

Coordinates of
point 2

−100.0

{0.1 %}

100.0

1 X (P2)

100.0 Analog setpoint of P2

100 % = max. input value (5 V, 10 V or 20 mA)

2 Y (P2)

100.0 Output frequency of P2

100 % = C0011

Advertising