Function library

Optimising the operating behaviour
Oscillation damping

10

l

272

EDS82EV903 EN 3.0

10.3.3

Oscillation damping

Description

Suppression of idling oscillations when:

ƒ

the rated power of controller and motor of a drive do not match, e.g. at operation
with high switching frequency and the related power derating

ƒ

Operation of higher−pole motors

ƒ

Operation of special motors

Compensation of resonances in the drive

ƒ

Some asynchronous motors can show this behaviour when being operated with an
output frequency of approx. 20 ... 40 Hz. As a result, operation can be instable
(current and speed fluctuations).

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0079 Oscillation

damping

2

0

{1}

140

^ 272

Adjustment

1. Approach with speed oscillations.

2. Reduce the speed oscillations by changing C0079 step by step. Additional indicators

for smooth running can be:
– uniform motor current
– reduction of mechanical vibrations in the bearing seat

)

Note!

Compensate the resonances in speed−controlled operation via the parameters
of the controller only.