Operation with rated power (normal operation)
Rated data for a mains voltage of 230 V
l
34
EDS82EV903 EN 3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
1.5
2.2
P
rated
[hp]
2.0
3.0
8200 vector type
EMC filter integrated
E82xV152K2C0xx
E82xV222K2C0xx
3)
Without EMC filter
E82xV152K2C2xx
E82xV222K2C2xx
3)
Mains
1/N/PE
3/PE
1/N/PE
3/PE
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
15.0
9.1
−
−
with mains choke
I
mains
[A]
12.5
6.3
18.0
9.0
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
−
1.1
−
0.4
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
7.0
9.5
4 kHz sin
8 kHz sin
I
r
[A]
7.0
9.5 (E82CV...: 8.5)
16 kHz sin
2)
I
r
[A]
4.6
6.2
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
10.5
14.2
4 kHz sin
8 kHz sin
I
max
[A]
10.5
14.2
16 kHz sin
2)
I
max
[A]
6.9
9.3
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
100
130
E82DV... inside/outside
P
loss
[W]
33/67
43/87
E82CV... inside/cooler
P
loss
[W]
33/67
43/87
Dimensions
Dependent on the mounting variant (
^ 61)
Mass
E82EV...
m [kg]
1.6
E82DV...
m [kg]
1.6
E82CV...
m [kg]
1.1
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if
J reaches max. − 5 °C
3)
Operation only permitted with mains choke (
^ 106)