Function library, Code table – Lenze E82xVxxxKxxxxx User Manual

Page 430

Advertising
background image

Function library

Code table

10

l

430

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0425
*

v

Configuration −
single−track
frequency
input X3/E1
(DFIN1)

2

f

r

Df

min

t

f

max

l

f

N

= normalisation frequency

– f

N

corresponds to C0011

l

Df

min

= resolution

l

t = sampling rate
– The lower the sampling rate

the higher the dynamics

l

f

max

= maximum frequency

which can be operated
depending on C0425
– Set C0425 so that, at

maximum motor speed, the
frequency supplied by the
encoder is lower than f

max

l

Activate the frequency input
with C0410/24 = 1

l

Adjust the frequency input
with C0426 and C0427

^ 303

0

100 Hz

1/200

1 s

300 Hz

1

1 kHz

1/200

100 ms

3 kHz

2

10 kHz

1/200

10 ms

10 kHz

3

10 kHz

1/1000

50 ms

10 kHz

4

10 kHz

1/10000 500 ms

10 kHz

5 (A)

102.4

kHz

1/400

2 ms

102.4

kHz

6 (A)

102.4

kHz

1/1000

5 ms

102.4

kHz

7 (A)

102.4

kHz

1/2000

10 ms

102.4

kHz

Configuration −
two−track
frequency
input X3/E1,
X3/E2 (DFIN1)

10

100 Hz

1/200

1 s

300 Hz

11

1 kHz

1/200

100 ms

3 kHz

12 (A)

10 kHz

1/200

10 ms

10 kHz

13 (A)

10 kHz

1/1000

50 ms

10 kHz

14 (A)

10 kHz

1/10000 500 ms

10 kHz

15 (A)

102.4

kHz

1/400

2 ms

102.4

kHz

16 (A)

102.4

kHz

1/1000

5 ms

102.4

kHz

17 (A)

102.4

kHz

1/2000

10 ms

102.4

kHz

C0426
*

Frequency
input gain
X3/E1, X3/E2
(A) (DFIN1−
GAIN)

100

−1500.0

{0.1 %}

1500.0

C0426 +

f

N

@ p

z @ C0011 @ 100 %

l

f

N

= normalisation frequency

from C0425

l

p = number of motor pole pairs

l

z = number of encoder
increments

l

C0011 = maximum output
frequency (corresponds to
maximum process motor
speed)

C0427
*

Offset for
frequency
input X3/E1,
X3/E2 (A)
(DFIN1−OFFSET)

0.0

−100.0

{0.1 %}

100.0

C0428
*
(A)

Gain for
frequency
output
(DFOUT1−OUT)

100

0.0

{0.1 %}

1500.0

Advertising