Technical data

Operation with rated power (normal operation)

Rated data for 500 V mains voltage

4

l

47

EDS82EV903 EN 3.0

Typical motor power
Three−phase asynchronous
motor (4−pole)

P

rated

[kW]

7.5

11

P

rated

[hp]

10.0

15

8200 vector type

EMC filter integrated

E82xV752K4C0xx

E82xV113K4C0xx

3)

Without EMC filter

E82xV752K4C4xx

E82xV113K4C2xx

3)

Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)

without mains choke

I

mains

[A]

17.2

with mains choke

I

mains

[A]

12.0

16.8

Output power +U

DC

, −U

DC

1)

P

DCres

[kW]

1.5

0

Rated output
current at
switching
frequency

2 kHz sin

I

r

[A]

13.2

18.8

4 kHz sin

8 kHz sin

I

r

[A]

13.2

18.8

16 kHz sin

2)

I

r

[A]

8.6

12.2

Max. permissible
output current for
60 s at switching
frequency

2 kHz sin

I

max

[A]

24.8

35.3

4 kHz sin

8 kHz sin

I

max

[A]

24.8

35.3

16 kHz sin

2)

I

max

[A]

12.9

18.3

Power loss (operation with I

N8

)

E82EV...

P

loss

[W]

300

410

E82DV... inside/outside

P

loss

[W]

100/200

137/273

E82CV... inside/cooler

P

loss

[W]

100/200

137/273

Dimensions

Dependent on the mounting variant (

^ 61)

Mass

E82EV...

m [kg]

3.6

E82DV...

m [kg]

3.6

E82CV...

m [kg]

3.0

1)

Power supplied by the DC bus when operating with power−adapted motor

2)

Switching frequency is reduced to 4 kHz if

J reaches max. − 5 °C

3)

Operation only permitted with mains choke or mains filter (

^ 106)

Advertising