Function library – Lenze E82xVxxxKxxxxx User Manual

Page 305

Advertising
background image

Function library

Configuration of analog and digital setpoints and actual values

Digital setpoints via frequency input

10

l

305

EDS82EV903 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0428
*
(A)

Gain for
frequency
output
(DFOUT1−OUT)

100

0.0

{0.1 %}

1500.0

C0435
*

v

(A)

Automatic
adjustment of
frequency
input

0

0
= inactive

{1}

4096

l

Only required for speed control
with digital feedback via HTL
encoder

l

Calculates the gain C0426,
depending on C0425 and
C0011

l

C0426 is recalculated after
every change in C0011 or
C0425

l

Always enter the number of
increments divided by the
number of motor pole pairs!
– Example: number of encoder

increments = 4096, 4−pole
motor

Þ C0435 = 2048

Activation

1. If you use X3/E1 or X3/E1 and X3/E2 as frequency inputs, you must ensure that the

inputs are not connected to other digital signals:
– These connections must be removed under C0410
– Otherwise the controller will evaluate the digital setpoint signal in a wrong way!

(

516 ff)

2. Assign the signal source "frequency input" to the required setpoint or actual value

under C0412 (C0412/x = 2).

3. Activation of frequency input with C0410/24 = 1.

)

Note!

ƒ

In addition to the free configuration under C0412 you can also use the fixed
assignment under C0007 and C0005:

ƒ

Use C0007 to link the function with a digital input.

ƒ

Use C005 to select a configuration which evaluates the frequency input.