4 lateral mounting, Lateral mounting, Mechanical installation – Lenze E82xVxxxKxxxxx User Manual
Page 77
![background image](/manuals/566070/77/background.png)
Mechanical installation
Standard devices in a power range from 3 ... 11 kW
Lateral mounting
l
77
EDS82EV903−3.0
5.3.4
Lateral mounting
For this mounting variant you require the controller type E82EV...
)
Note!
This mounting variant does not enable a CE−typical drive system to be
installed.
Lateral mounting of the controller is possible on both sides. The controller is either fixed
or can be swivelled depending on the mounting point. Both mounting types use the same
mounting kit.
Fixed lateral mounting
ƒ
A mounting set is required for all controllers:
– Order number E82ZJ005 for 8200 vector 3 ... 4 kW (230 V)
– Order number E82ZJ006 for 8200 vector 5.5 ... 7.5 kW (230 V)
– Order number E82ZJ005 for 8200 vector 3 ... 5.5 kW (400/500 V)
– Order number E82ZJ006 for 8200 vector 7.5 ... 11 kW (400/500 V)
8200vec074
Fig. 5−14
Fixed lateral mounting
Bolt here
Dimensions [mm]
8200 vector
Mounting set
a
b
b
1
b
2
c
1
d
e
E82EV302K2C
E82EV402K2C
E82ZJ005
100
306
280 ... 295
240
162
6.5
39
E82EV552K2C
E82EV752K2C
E82ZJ006
125
E82EV302K4C
E82EV402K4C
E82EV552K4C
E82ZJ005
100
E82EV752K4C
E82EV113K4C
E82ZJ006
125
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 14 mm.