User guidelines, Example, Sflow sampling – Dell POWEREDGE M1000E User Manual

Page 1469: Syntax, Default configuration

Advertising
background image

Sflow Commands

1465

User Guidelines

This command has no user guidelines.

Example

console(config-if-1/0/2)#sflow 1 polling 6055

sflow sampling

Use the sflow sampling command to enable a new sflow sampler instance for

this data source if rcvr_idx is valid. Use the “no” form of this command to

reset sampler parameters to the default.

Syntax

sflow

rcvr-index

sampling {gigabitethernet | tengigabitethernet}

interfac-

list

sampling-rate

[

size

]

no sflow

rcvr-index

sampling {gigabitethernet | tengigabitethernet}

interface-list

rcvr-index

—The sFlow Receiver for this sFlow sampler to which flow

samples are to be sent. If no receiver is configured, then no packets will be

sampled. Only active receivers can be set. If a receiver expires, then all

samplers associated with the receiver will also expire. (Range: 1–8).

interface-list

— The list of interfaces to poll in unit/slot/port format.

sampling-rate

—The statistical sampling rate for packet sampling from this

source. A sampling rate of 1 counts all packets. A rate of 0 disables

sampling. A value of n means that out of n incoming packets, 1 packet will

be sampled. (Range: 1024–65536).

size

—The maximum number of bytes that should be copied from the

sampler packet (Range: 20–256 bytes).

Default Configuration

There are no samplers configured by default.
The default sampling rate is 0.
The default maximum header size is 128.

2CSPC4.XModular-SWUM200.book Page 1465 Thursday, March 10, 2011 11:18 AM