User Guidelines

Each domain must have a unique name and level, for example, one cannot

create a domain qwerty at level 2 if domain qwerty already exists at level 1.

Likewise, one cannot create a domain dvorak at level 2 if a domain of any

name exists at level 2.

Example

In this example, a domain vin is created at level 1.

console(config)#ethernet cfm domain vin level 1

console(config-cfm-mdomain)#

service

Use the service command in maintenance domain config mode to associate a

VLAN with a maintenance domain. Use the no form of the command to

remove the association.

Syntax

service

service-name

vlan

vlanid

Parameter Description

Default Configuration

No VLANs are associated with a maintenance domain by default.

Parameter

Description

Range

Default

Access

service

Unique service

identifier

alphanumeric

string

None

Read-write

Maintenance

association

VLAN ID

VLAN ID

representing a

service instance

that is

monitored by

this

maintenance

association.

1-4093

0

Read-write