Command mode, User guidelines, Example – Dell POWEREDGE M1000E User Manual

Page 1470: Sflow sampling (interface mode), Syntax, Default configuration

Advertising
background image

1466

Sflow Commands

Command Mode

Global Configuration mode.

User Guidelines

This command has no user guidelines.

Example

console(config)#sflow 1 sampling gigabitethernet

1/0/2 1500 50

sflow sampling (Interface Mode)

Use the sflow sampling command in Interface Mode to enable a new sflow

sampler instance for this data source if rcvr_idx is valid. Use the "no" form of

this command to reset sampler parameters to the default.

Syntax

sflow

rcvr-index

sampling

sampling-rate

[

size

]

no sflow

rcvr-index

sampling

rcvr-index

— The sFlow Receiver for this sFlow sampler to which flow

samples are to be sent. If no receiver is configured, then no packets will be

sampled. Only active receivers can be set. If a receiver expires, then all

samplers associated with the receiver will also expire. (Range: 1 - 8).

sampling-rate

— The statistical sampling rate for packet sampling from

this source. A sampling rate of 1 counts all packets. A rate of 0 disables

sampling. A value of n means that out of n incoming packets, 1 packet will

be sampled. (Range: 1024 - 65536).

size

— The maximum number of bytes that should be copied from the

sampler packet (Range: 20 - 256 bytes).

Default Configuration

There are no samplers configured by default.
The default sampling rate is 0.
The default maximum header size is 128.

2CSPC4.XModular-SWUM200.book Page 1466 Thursday, March 10, 2011 11:18 AM