Serial Peripheral Interface (SPI)

MPC8260 PowerQUICC II Family Reference Manual, Rev. 2

38-12

Freescale Semiconductor

38.5.1

Receive/Transmit Function Code Registers (RFCR/TFCR)

Figure 38-9

shows the fields in the receive/transmit function code registers (RFCR/TFCR).

Table 38-6

describes the RFCR/TFCR fields.

38.6

SPI Commands

Table 38-7

lists transmit/receive commands sent to the CP command register (CPCR).

2

Normally, these parameters need not be accessed. They are listed to help experienced users in debugging.

0

1

2

3

4

5

6

7

Field

GBL

BO

TC2

DTB

Reset

0000_0000

R/W

R/W

Addr

SPI Base + 04 (RFCR)/SPI Base + 05 (TFCR)

Figure 38-9. RFCR/TFCR—Function Code Registers

Table 38-6. RFCR/TFCR Field Descriptions

Bits

Name

Description

0–1

Reserved, should be cleared.

2

GBL

Global access bit
0 Disable memory snooping
1 Enable memory snooping

3–4

BO

Byte ordering. Set BO to select the required byte ordering for the buffer. If BO is changed on-the-fly,
it takes effect at the beginning of the next frame or BD.
00 True little-endian. Note this mode can only be used with 32-bit port size memory.
01 Munged little-endian
1x Big-endian

5

TC2

Transfer code 2. Contains the transfer code value of TC[2], used during this SDMA channel memory
access. TC[0–1] is driven with a 0b11 to identify this SDMA channel access as a DMA-type access.

6

DTB

Data bus indicator.
0 Use 60x bus for SDMA operation.
1 Use local bus for SDMA operation.

7

Reserved, should be cleared.

Table 38-7. SPI Commands

Command

Description

INIT

TX

PARAMETERS

Initializes all transmit parameters in the parameter RAM to their reset state and should be issued
only when the transmitter is disabled. The

INIT

TX

AND

RX

PARAMETERS

command can also be used

to reset both the Tx and Rx parameters.