Table 18-1. tgcr1 field descriptions, Timer global configuration register 1 (tgcr1) -4, Tgcr1 field descriptions -4 – Freescale Semiconductor MPC8260 User Manual

Page 640: Hown in, Figure 18-3

Advertising
background image

Timers

MPC8260 PowerQUICC II Family Reference Manual, Rev. 2

18-4

Freescale Semiconductor

Table 18-1

describes TGCR1 fields.

The TGCR2 register is shown in

Figure 18-4

.

0

1

2

3

4

5

6

7

Field

CAS2

STP2

RST2

GM1

STP1

RST1

Reset

0000_0000

R/W

R/W

Addr

0x0x10D80

Figure 18-3. Timer Global Configuration Register 1 (TGCR1)

Table 18-1. TGCR1 Field Descriptions

Bits

Name

Description

0

CAS2

Cascade timers.
0 Normal operation.
1 Timers 1 and 2 cascade to form a 32-bit timer.

1

Reserved, should be cleared.

2

STP 2

Stop timer.
0 Normal operation.
1 Reduce power consumption of the timer. This bit stops all clocks to the timer, except the clock

from the internal bus interface, which allows the user to read and write timer registers. The clocks
to the timer remain stopped until the user clears this bit or a hardware reset occurs.

3

RST2

Reset timer.
0 Reset the corresponding timer (a software reset is identical to an external reset).
1 Enable the corresponding timer if the STP bit is cleared.

4

GM1

Gate mode for TGATE1. This bit is valid only if the gate function is enabled in TMR1 or TMR2.
0 Restart gate mode. TGATE1 is used to enable/disable count. A falling TGATE1 enables and

restarts the count and a rising edge of TGATE1 disables the count.

1 Normal gate mode. This mode is the same as 0, except the falling edge of TGATE1 does not

restart the count value in TCN.

5

Reserved, should be cleared.

6

STP1

Stop timer.
0 Normal operation.
1 Reduce power consumption of the timer. This bit stops all clocks to the timer, except the clock

from the internal bus interface, which allows the user to read and write timer registers. The clocks
to the timer remain stopped until the user clears this bit or a hardware reset occurs.

7

RST1

Reset timer.
0 Reset the corresponding timer (a software reset is identical to an external reset).
1 Enable the corresponding timer if STP = 0.