22. Serial I/O with FIFO (SIOF)

Rev.1.00 Jan. 10, 2008 Page 1110 of 1658
REJ09B0261-0100

22.3.5

Transmit Control Data Register (SITCR)

SITCR is a 32-bit readable/writable register that specifies transmit control data of the SIOF. The
setting of SITCR is valid only when bits FL3 to FL0 in SIMDR are set to 1xxx (x: any value).

SITCR is initialized by the conditions shown in table 22.3, Register State in Each Operating
Mode, or by a transmit reset by the TXRST bit in SICTR.

16

17

18

19

20

21

22

23

24

25

26

27

28

29

31

30

SITC0[15:0]

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

BIt:

Initial value:

R/W:

0

1

2

3

4

5

6

7

8

9

10

11

12

13

15

14

SITC1[15:0]

BIt:

Initial value:

R/W:

Bit Bit

Name

Initial
Value R/W Description

31 to 16 SITC0[15:0] H'0000

R/W

Control Channel 0 Transmit Data

These bits specify data to be output from the
SIOF_TXD pin as control channel 0 transmit data. The
position of the control channel 0 data in the transmit or
receive frame depends on the value set in the CD0A bit
in SICDAR.

• These bits are valid when the CD0E bit in SICDAR

is set to 1.

15 to 0

SITC1[15:0] H'0000

R/W

Control Channel 1 Transmit Data

These bits specify data to be output from the
SIOF_TXD pin as control channel 1 transmit data. The
position of the control channel 1 data in the transmit or
receive frame depends on the CD1A bit in SICDAR.

• These bits are valid when the CD1E bit in SICDAR

is set to 1.