19. Display Unit (DU)

Rev.1.00 Jan. 10, 2008 Page 967 of 1658

REJ09B0261-0100

19.5.6

CLAMP Signal and DE Signal

The display unit (DU) generates a CLAMP signal and DE signal, independent of the DISP signal
indicating the display interval.

The rising-edge start position and high-level width of the CLAMP signal and DE signal, with
reference to the HSYNC signal falling edge, can be set in dot clock units. Figure 19.20 shows the
timing chart.

However, the DE signal is fixed at low level during the vertical blanking interval.

DCLKOUT
(output)

HSYNC signal

CLAMP signal/
DE signal

CLAMP signal/
DE signal

CLAMP signal/
DE signal

Starting position value
+ 1

High-level width value

The minimum value of rising position = 1

Start position value
+ 1

High-level width value

When the HSYNC
signal falls, the
CLAMP signal/DE
signal also falls.

When start position value is 0

When (start position value + high-level width value) exceeds the HSYNC period

Figure 19.20 CLAMP Signal and DE Signal