3 operation control register (opcr) – Renesas SH7781 User Manual

Page 1209

Advertising
background image

24. Multimedia Card Interface (MMCIF)

Rev.1.00 Jan. 10, 2008 Page 1179 of 1658

REJ09B0261-0100

Bit:

Initial value:

R/W:

7

6

5

4

3

2

1

0

0

0

0

0

0

0

0

0

R

CMD

START

R

R

R

R

R

R

R/W

Bit Bit

Name

Initial
Value R/W Description

7 to 1

All 0

R

Reserved

These bits are always read as 0. The write value should
always be 0.

0

CMDSTART 0

R/W

Starts command transmission when 1 is written. This bit
is automatically cleared to 0 after the MMCIF received
the CMDSTART command. When 0 is written to this bit,
operation is not affected.

24.3.3

Operation Control Register (OPCR)

OPCR is an 8-bit readable/writable register that aborts command operation, and suspends or
continues data transfer.

Bit:

Initial value:

R/W:

7

6

5

4

3

2

1

0

0

0

0

0

0

0

0

0

R/W

DATAEN

RD_

CONTI

CMD

OFF

R

R/W

R/W

R

R

R

R

Bit Bit

Name

Initial
Value R/W Description

7 CMDOFF

0 R/W

Command

Off

Aborts all command operations (MMCIF command
sequence) when 1 is written after a command is
transmitted. This bit is cleared to 0 automatically after
the MMCIF received the CMDOFF command.

Write enabled period: From command transmission
completion to command sequence end

Write of 0: Operation is not affected.

Write of 1: Command sequence is forcibly aborted.

Note: Do not write to this bit out of the write enable

period.