5. Exception Handling

Rev.1.00 Jan. 10, 2008 Page 90 of 1658
REJ09B0261-0100

Table 5.2

States of Register in Each Operating Mode

Register Name

Abbr.

Power-on
Reset

Manual Reset Sleep

Standby

TRAPA exception register

TRA

Undefined

Undefined

Retained

Retained

Exception event register

EXPEVT

H'0000 0000 H'0000 0020

Retained

Retained

Interrupt event register

INTEVT

Undefined

Undefined

Retained

Retained

Non-support detection exception
register

EXPMASK H'0000 0013 H'0000 0013

Retained

Retained

5.2.1

TRAPA Exception Register (TRA)

The TRAPA exception register (TRA) consists of 8-bit immediate data (imm) for the TRAPA
instruction. TRA is set automatically by hardware when a TRAPA instruction is executed. TRA
can also be modified by software.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

Bit:

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Initial value:

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R/W

R/W

R/W

TRACODE

R/W

R/W

R/W

R

R

R/W:

Bit:

Initial value:

R/W:

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

0

0

0

0

0

0

R

R

R

R

R

R

R/W

R/W

Bit

Bit Name

Initial Value R/W

Description

31 to 10

⎯ All

0 R

Reserved

For details on reading/writing this bit, see General
Precautions on Handling of Product.

9 to 2

TRACODE

Undefined

R/W

TRAPA Code

8-bit immediate data of TRAPA instruction is set

1, 0

⎯ All

0 R

Reserved

For details on reading/writing this bit, see General
Precautions on Handling of Product.