3 manual reset by watchdog timer overflow – Renesas SH7781 User Manual

Page 809

Advertising
background image

16. Watchdog Timer and Reset (WDT)

Rev.1.00 Jan. 10, 2008 Page 779 of 1658

REJ09B0261-0100

16.5.3

Manual Reset by Watchdog Timer Overflow

The time period taken by manual reset on watchdog timer overflow (WDT manual reset holding
time) is equal to or more than 30 cycles of the peripheral clock (Pck).

The transition time from watchdog timer overflow to the manual reset state (WDT reset setup
time) is equal to or more than eight cycles of the peripheral clock (Pck).

(1)

Manual Reset Caused by Watchdog Timer Overflow during Normal Operation

The timing of indicating the reset state or normal operation on the STATUS[1:0] pins is
synchronous with the peripheral clock (Pck), and is therefore asynchronous with the clocks input
from the EXTAL pin and the CLKOUT pin.

WDT reset setup time

WDT manual reset holding time

WDT overflow
signal

CLKOUT
output

STATUS[1:0]
output

HH (reset)

LL (normal)

LL (normal)

EXTAL
input

CLKOUTENB
output

MRESETOUT
output

Figure 16.8 STATUS Output by Manual Reset Caused by WDT Overflow

during Normal Operation

Advertising