2 control signal timing, 0 to 3.6 v, v, 30 pf – Renesas SH7781 User Manual

Page 1602

Advertising
background image

32. Electrical Characteristics

Rev.1.00 Jan. 10, 2008 Page 1572 of 1658
REJ09B0261-0100

t

MDRH

PRESET

MODE13 to MODE11

MODE8 to MODE5

t

MDRS

t

PRr

t

PRf

Figure 32.6 MODE Pin Setup/Hold Timing

32.3.2

Control Signal Timing

Table 32.7 Control Signal Timing

Conditions: V

DDQ

= 3.0 to 3.6 V, V

DD

= 1.1 V, Ta =

−20 to +85/−40 to +85°C, C

L

= 30 pF

Item Symbol

Min.

Max.

Unit

Figure

BREQ setup time*

t

BREQS

3 — ns

BREQ hold time

t

BREQH

1.5 — ns

BREQ delay time

t

BACKD

— 6

ns

Bus tri-state delay time

t

BOFF1

— 12 ns

Bus buffer on time

t

BON1

— 12 ns

32.7

STATUS0, STATUS1 delay time

t

STD

6 ns

32.8

Note: * t

cyc

is the period of one CLKOUT cycle.