24. Multimedia Card Interface (MMCIF)

Rev.1.00 Jan. 10, 2008 Page 1199 of 1658

REJ09B0261-0100

Bit Bit

Name

Initial
Value R/W Description

6

RTY6

0

R/W

Response Type 5

Sets data busy status from the MMC card.

This bit is set to perform CRC check for the response
(R2 response of MMC mode) when the command that
reads, as a response, the register value of the
multimedia card, including CRC7, is executed.

RTY2 to RTY0 must be set to 101.

5

RTY5

0

R/W

Response Type 5

Sets data busy status from the MMC card.

0: A command without data busy

1: A command with data busy

4

RTY4

0

R/W

Response Type 4

Specifies that the command response CRC is checked
through CRC7. Bits RTY2 to RTY0 should be set to
100.

0: Does not check CRC through CRC7

1: Checks CRC through CRC7

3

⎯ 0

R

Reserved

These bits are always read as 0. The write value should
always be 0.

2

1

0

RTY2

RTY1

RTY0

0

0

0

R/W

R/W

R/W

Response Types 2 to 0

These bits specify the number of command response
bytes.

000: A command needs no command response.

001: Setting prohibited

010: Setting prohibited

011: Setting prohibited

100: A command needs 6-byte command responses.

Specified by R1, R1b, R3, R4, and R5 responses.

101: A command needs a 17-byte command response.

Specified by R2 response.

110: Setting prohibited

111: Setting prohibited