7 transmit and receive procedures – Renesas SH7781 User Manual

Page 1169

Advertising
background image

22. Serial I/O with FIFO (SIOF)

Rev.1.00 Jan. 10, 2008 Page 1139 of 1658

REJ09B0261-0100

22.4.7

Transmit and Receive Procedures

Set each register after setting the PFC.

(1)

Transmission in Master Mode

Figure 22.9 shows an example of settings and operation for master mode transmission.

Start

End

Set the SCKE bit in SICTR to 1

Start SIOF_SCK output

Set SITDR

Set the TXE bit in SICTR to 0

Transmit SITDR from SIOF_TXD

synchronously with SIOF_SYNC

TDREQ = 1

Transfer ended?

No

Yes

No

Yes

No.

1

2

3

4

5

6

7

8

Flowchart

SIOF Settings

SIOF Operation

Set operation start for baud rate generator

Output serial clock

Set transmit data

Set to disable transmission

End transmission

Set the start for frame synchronous signal

output and enable transmission

Output frame

synchronous signal and

issue transmit transfer

request*

Transmit

Note: * When interrupts due to transmit data underflow are enabled, after setting the no. 6 transmit data, the TXE bit should be set to 1.

Set SIMDR, SISCR, SITDAR,

SIRDAR, SICDAR, SITCR,

and SIFCTR

Set the FSE and TXE bits in SICTR to 1

Set operating mode, serial clock, slot

positions for transmit/receive data, slot

position for control data, and FIFO

request threshold value

Figure 22.9 Example of Transmit Operation in Master Mode

Advertising