22. Serial I/O with FIFO (SIOF)

Rev.1.00 Jan. 10, 2008 Page 1145 of 1658

REJ09B0261-0100

(2)

Regarding Transmit and Receive Classification

The transmit sources and receive sources are signals indicating the state; after being set, if the state
changes, they are automatically cleared by the SIOF.

When the DMA transfer is used, a DMA transfer request is pulled low for one cycle at the end of
DMA transfer.

(3)

Processing when Errors Occur

On occurrence of each of the errors indicated as a status in SISTR, the SIOF performs the
following operations.

• Transmit FIFO underflow (TFUDF)

The immediately preceding transmit data is again transmitted.

• Transmit FIFO overflow (TFOVF)

The contents of the transmit FIFO are protected, and the write operation causing the overflow
is ignored.

• Receive FIFO overflow (RFOVF)

Data causing the overflow is discarded and lost.

• Receive FIFO underflow (RFUDF)

An undefined value is output on the bus.

• Frame synchronization error (FSERR)

The internal counter is reset according to the signal in which an error occurs.

• Slot assign error (SAERR)

⎯ If the same slot is assigned to both serial data and control data, the slot is assigned to serial

data.

⎯ If the same slot is assigned to two control data items, the data cannot be transferred

correctly.