6. Floating-Point Unit (FPU)

Rev.1.00 Jan. 10, 2008 Page 134 of 1658
REJ09B0261-0100

Bit Bit

Name

Initial
Value R/W

Description

17 to 12 Cause

All 0

R/W

11 to 7

Enable

All 0

R/W

6 to 2

Flag

All 0

R/W

FPU Exception Cause Field

FPU Exception Enable Field

FPU Exception Flag Field

Each time an FPU operation instruction is executed, the
FPU exception cause field is cleared to 0. When an
FPU exception occurs, the bits corresponding to FPU
exception cause field and flag field are set to 1. The
FPU exception flag field remains set to 1 until it is
cleared to 0 by software.
For bit allocations of each field, see table 6.3.

1

0

RM1

RM0

0

1

R/W

R/W

Rounding Mode

These bits select the rounding mode.

00: Round to Nearest

01: Round to Zero

10: Reserved

11: Reserved