12. DDR2-SDRAM Interface (DBSC2)

Rev.1.00 Jan. 10, 2008 Page 540 of 1658
REJ09B0261-0100

MCK0,
MCK1

MA[14:11]
MA[9:0]

MBA[2:0]

MCKE

MCS

MRAS

MCAS

MWE

MA[10]

ACT

bank A

READ
bank A

Invalid

Invalid

Invalid

Invalid

MDQS[3:0]

MDQ[31:0]

MDM[3:0]

Invalid

Invalid

Invalid

Invalid

PALL

Invalid

Invalid

REF

SDRAM
command

tRAS
= 9 cycles

Read data

tRC
= 12 cycles

tRP
= 3 cycles

Example of CL = 3

Valid

Valid

Valid

Valid

Valid

Valid

High level

Figure 12.17 tRC

Figure 12.17 shows an example of performing auto-refresh after read access of bank A, the page
for which had been closed. After issuing an ACT command and READ command for bank A and
performing data reading, a PALL command must be used to close all banks in order to perform
auto-refresh. In order to issue the PALL command, the tRAS time constraint must be satisfied, and
issuing of the PALL command is delayed until this time. Then, when issuing the REF command,
both of time constraints tRP and tRC must be satisfied simultaneously. When these constraints are
both satisfied, the REF command is issued and auto-refresh is performed.