32. Electrical Characteristics

Rev.1.00 Jan. 10, 2008 Page 1569 of 1658

REJ09B0261-0100

Item Symbol

Min.

Max.

Unit

Figure

MODE13 to MODE11,
MODE8 to MODE5

t

MDRH

20

⎯ ns

32.6

MODE reset hold time

MODE14, MODE10,
MODE9, MODE4 to
MODE0

32.4

PRESET assert time

t

RESW

20

t

cyc

32.4

PLL synchronization settling time

t

PLL

400

μs 32.5

TRST reset hold time

t

TRSTRH

0

⎯ ns

32.4

PRESET input rise time

t

PRr

⎯ 20 μs 32.6

PRESET input fall time

t

PRf

⎯ 20 μs 32.6

Notes: 1. With a crystal resonator connected on EXTAL and XTAL, the maximum frequency is 34

MHz. When using a third-order overtone crystal resonator, a tank circuit must be
connected externally.

2. The load capacitance connected on the CLKOUT pin should be not greater than 50 pF.

3.

t

cyc

is the period of one CLKOUT clock cycle.

4. This applies to clock operating modes 0, 1, 2, and 3 (see table 15.2).

5. This applies to clock operating modes 8, 9, 10, and 11 (see table 15.2).

6. This applies to clock operating modes 16, 17, 18, and 19 (see table 15.2).

Note: When the clock is input from the EXTAL pin.

t

EXcyc

t

EXH

t

EXL

t

EXr

t

EXf

1/2V

DDQ

V

IH

V

IH

V

IL

V

IL

V

IH

1/2V

DDQ

Figure 32.1 EXTAL Clock Input Timing