9400 HighLine | Parameter setting & configuration

Motor interface

Parameter setting | Motor monitoring (I²xt)

100

Firmware 1.37 - 09/2006

L

Speed-dependent evaluation of the motor current
By selecting a characteristic in

C01196/1...8

the permissible motor current is evaluated

depending on speed for calculating the thermal motor utilisation.

r

The speed-dependent evaluation can be more or less switched off by setting

C01196/

1...8

to "100 %" each. The calculation simplified due to this setting corresponds to the

calculation in previous devices (e.g. servo inverter 9300 or ECS).

Parameters

Characteristic point

C01196/1

n

1

/n

n

Speed = "0" (standstill)

C01196/2

I

1

/I

n

Permissible motor current at standstill

C01196/3

n

2

/n

n

Speed from which the torque must be reduced with self-ventilated motors.

• Below this speed the cooling air flow of the integral fan is not sufficient

anymore.

C01196/4

I

2

/I

n

Permissible motor current at speed n

2

(torque reduction)

C01196/5

n

3

/n

n

Rated speed

C01196/6

I

3

/I

n

Permissible motor current at rated speed

C01196/7

n

4

/n

n

Speed above the rated speed (in the field weakening in case of asynchronous

motors)

C01196/8

I

4

/I

n

Permissible motor current at speed n

4

(field weakening)

Note!

Self-ventilated standard motors are protected insufficiently by setting

C01196/

1...8

to "100 %" each at low speeds.

Servo motors, however, do not have a point from which the torque must be

reduced due to a too low speed.
• When setting the characteristic in

C01196/1...8

this point must not be

ignored. Hence, point 2 is to be set ideally to point 1 or point 3.

Advertising