2 actual value and status signals, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 268

Advertising
background image

9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – torque" | Assignment of the I/O terminals

268

Firmware 1.37 - 09/2006

L

11.3.2.2

Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for

the technology application "actuator – torque".

r

The default signal configuration if required can be easily changed by parameterising

the multiplexer parameters assigned.

Analog outputs

Digital outputs

State bus

Terminal X3

Signal (Lenze setting)

Signal configuration

AO1

Motor speed

• Scaling: ±10 V ≡ motor reference speed (

C00011

)

C03110/1

AO2

Motor torque (setpoint)

• Scaling: ±10 V ≡ Motor reference torque (

C00057/2

)

C03110/2

I/O terminals Analog outputs (C 120)

Terminal X4

Signal (Lenze setting)

Signal configuration

DO1

Status "Drive ready"

• This operating state is active if the controller is enabled by setting

the digital input RFR to HIGH level and no error has occurred.

C03100/1

DO2

Status "Torque follower enabled"

• The torque follower has been enabled via the digital input DI2.

C03100/2

DO3

Status "Torque follower in limitation"

• If the torque follower is enabled, the torque setpoint or the

current setpoint are within the limitation.

C03100/3

DO4

Status "Error active acknowledgement is required"

• Monitoring with the error response "Error" or "Quick stop by

trouble" has been activated, and the controller is in the device

state "Error active" or "Quick stop by trouble active".

C03100/4

I/O terminals Digital outputs (C 125)

Terminal X2

Signal (Lenze setting)

Signal configuration

SB

Status "Torque follower in limitation"

• If the torque follower is enabled, the torque setpoint or the

current setpoint are within the limitation.

• The state bus is put in the "error" status.

C03100/5

I/O terminals Monitoring function "State bus" (C 127)

GA

AO1

AO2

GO

24O

DO1

DO2

DO3

DO4

GE

24E

SB