5 speed limit value conditioning, Speed limit value conditioning (c 273), 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 273

Advertising
background image

L

Firmware 1.37 - 09/2006

273

9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – torque" | Speed limit value conditioning

11.3.5

Speed limit value conditioning

[11-17] Speed limit value conditioning (schematic diagram)

The speed limit value is defined in the Lenze setting via the analog input 2.

r

The defined speed limit value refers to the direction of rotation which can be set freely

with positive torque.

r

The speed limit value in negative direction of rotation equals, according to amount, the

limit value for the positive direction of rotation.

r

If the speed of the drive is inside the limitations, the motor generates the specified

torque.

r

If the positive or negative speed limit value (for CW or CCW rotation) is reached, the

drive changes to the speed-controlled operation. The set speed limit values are not

exceeded.

r

If the specified speed limit value directly corresponds to the line speed, the internal

limit value can be increased by entering an offset in C03008.

r

Parameter setting: Tab Application parameter  Dialog level Overview

Offset

Selection

LS_Torque...

M

Torque
setpoint

DI2

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed limit

AIN2

M

v

F

Parameters

Lenze setting

Value Unit

C03008

Offset for limit speed

0.00 %

Setpoint inputs of the function

Signal configuration

Lenze setting

Setpoint input

(Multiplexer parameters)

AIn 2  Upper limit speed

C03006

Inverted upper

limit speed



Lower speed limit value

C03171

Advertising