9400 HighLine | Parameter setting & configuration

I/O terminals

Digital outputs

7.5

Digital outputs

The controller has 4 freely configurable digital outputs.

7.5.1

Terminal assignment/electrical data

7.5.2

Parameter setting

Short overview of parameters for the digital outputs:

Note!

Initialisation behaviour:
• After mains switching up to the start of the application the digital outputs

remain set to FALSE.

Exception handling:
• In case of a critical exception in the application (e.g. reset) the digital outputs

are set to FALSE considering the terminal polarity parameterised in

C00118

.

Terminal

Use

Electrical data

X4/DO1

...

X4/DO4

Digital outputs 1 ... 4

LOW level: 0 ... +5 V

HIGH level: +15 ... +30 V

Output current: max. 50 mA per output (external

resistance > 480 Ω at 24 V)

Conversion rate: 1 kHz

X4/24O

External 24 V voltage supply for the digital outputs

X4/GO

Reference potential (digital ground)

GO

24O

DO1

DO2

DO3

DO4

X4

Parameter

Information

C00118

DOx terminal polarity

C00444

DOx status

C02802

Status word dig. outputs

Highlighted in grey = display parameter