1 parameter setting, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 201

Advertising
background image

L

Firmware 1.37 - 09/2006

201

9400 HighLine | Parameter setting & configuration

Basic drive functions

Limiter | Parameter setting

9.10.1

Parameter setting

r

Parameterisation dialog in the »Engineer«: Tab Application parameter  dialog level

Overview  All basic functions  Limiter

r

Short overview of the parameters for the limiter:

Parameters

Information

C02700

Software limit positions are active

C02701/1

Positive software limit position

C02701/2

Negative software limit position

C02702

Limitations effective

C02703

Max. speed

C02704

Max. speed (display in [rpm])

C02705

Max. acceleration

C02706

Min. S-ramp time

C02707

Permissible direction of rotation

C02708/1...4

Limited speed 1 .... 4

C02709/1...4

Limited speed 1 .... 4 (display in [rpm])

C02710/1...4

Delay lim. speed. 1 .... 4

C02711/1...4

S-ramp time lim. speed. 1 .... 4

C02712/1...4

Dec. time lim. speed. 1 .... 4

C02713

Max. path - manual jog

C02714

Max. path - manual jog (display in [increments])

C02715

Active limitation (status display)

C02716/1

Resp. to rotation limitation

C02716/2

Resp. to SW limit pos. excess

C02716/3

Resp. to max. value excess

Highlighted in grey = display parameter

Note!

The safety module has its own parameters.
Relevant to the basic function "Limiter" are the parameters of the safety

modules for setting "Limited direction of rotation", "speed with time limit" and

"Limited increment (position)".
Several other parameters of the safety module, however, do not have another

meaning for the basic function "Limiter", e.g. the parameters for configuring the

inputs of the safety module.