System block "LS_ManualJog"

The LS_ManualJog system block in the function block editor maps the basic function

"Manual jog".

Inputs

Identifier

DIS code | data type

Information/possible settings

MAN_bEnable

C02639/1

| BOOL

Requesting control via the basic function

TRUE If no other basic function is active, it is changed to the function state

"Manual jog active" and manual jog can be executed via the control

inputs.

TRUEÌFALSE An active manual jog is stopped, i. e. a changeover from the active

function state "Manual jog active" via the function state "Drive is

stopped" back to the basic state "Drive in standstill" is effected.

MAN_bJogPositive

C02639/2

| BOOL

Manual jog in positive/negative direction (C 159)

MAN_bJogNegative

C02639/3

| BOOL

MAN_bActivateJogSpeed2

C02639/4

| BOOL

Changeover to a second manual speed

FALSE Manual speed 1 (

C02620

) active.

TRUE Manual speed 2 (

C02621

) active.

MAN_bReleaseLimitSwitch

C02639/5

| BOOL

Retracting of an activated limit switch

TRUE Retracting from each activated limit switch towards the

corresponding retracting direction until the limit switch is enabled

again (not activated anymore) and the drive is located inside the

software limit positions set.

Afterwards the drive is braked to standstill with the deceleration set

unless the control input MAN_bJogPositive or MAN_bJogNegative is

activated for the corresponding retracting direction.

LS_ManualJog

MAN_bEnable

MAN_bJogNegative

MAN_bActivateJogSpeed2

MAN_bReleaseLimitSwitch

MAN_bEnabled

MAN_bActive

n

t

и

з

MAN_bJogPositive

MAN_dnState