Hardware limit positions (limit switch)
The travel range limits are monitored via limit switch inputs LIM_bLimitSwitchPositive and

LIM_bLimitSwitchNegative of the SB LS_Limiter.
Both inputs react to the TRUE status and must be connected to the corresponding digital

inputs which are connected with the limit switches.

[9-6]

Example: Connection of the travel range limit switches to the digital inputs 3 & 4

r

If the limit switch is activated, the drive axis is stopped automatically and a changeover

via the function state "Drive is stopped" to the function state "Error" is effected.

r

An error is caused via an internal system interface and entered in to the logbook of the

controller. The drive can only be traversed again when the error is acknowledged.

r

An activated limit switch can be retracted using the function "Retracting the limit

switch".

Retracting of an activated limit switch

(C 161)

r

When the limit switches are connected to the distributed terminals, both inputs

LIM_bLimitSwitchPositive and LIM_bLimitSwitchNegative of the SB

LS_Limiter

can be

connected via a bus system (e.g. system bus) with the distributed terminal.

See also:

Manual jog to limit position

(C 160)

X5

GI

RFR

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

LS_DigitalInput

DIGIN_bIn4

DIGIN_bIn3

LS_Limiter

LIM_bLimitSwitchPositive

LIM_bLimitSwitchNegative

Note!

If digital inputs for connecting the limit switch are to be fail-safe (activation at

LOW level), simply change the terminal polarity of the corresponding digital

inputs in

C00114

.