2 manual jog to limit position, Manual jog to limit position, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 160

Advertising
background image

9400 HighLine | Parameter setting & configuration

Basic drive functions

Manual jog | Executing manual jog

160

Firmware 1.37 - 09/2006

L

9.4.2.2

Manual jog to limit position

Manual jog to software limit position

[9-12] Example: Manual jog to positive software limit position

Manual jog to hardware limit position (limit switch)

[9-13] Example: Manual jog to positive limit switch

See also:

Software limit positions

(C 202)

Hardware limit positions (limit switch)

(C 204)

Note!

Detailed information on travel range monitoring via limit switches and software

limit positions can be found in the description of the basic function "

Limiter

".

(C 200)

n

Positive software limit position

r

When the reference is known and

the software limit positions are set,

a positioning to the corresponding

software limit positions unless the

manual jog has been manually

stopped by resetting

MAN_bJogNegative or

MAN_bJogPositive.

r

The drive brakes with the

deceleration set (

C02623

) to the

position of the corresponding

software limit position.

n

t

TRUE

FALSE

bJogPositive

t

Œ

n

Positive limit switch

o

Deceleration ramp of the quick stop function

r

When a limit switch is approached

during manual jog, the drive is

braked to standstill within the

deceleration time set for the quick

stop function.

n

t

TRUE

FALSE

bJogPositive

t

Œ



Advertising