9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 216

Advertising
background image

9400 HighLine | Parameter setting & configuration

Basic drive functions

Brake control | Parameter setting

216

Firmware 1.37 - 09/2006

L

Brake activation through time-out
If the waiting time for the brake activation is set > 0 s in

C02593

, time monitoring is active,

i.e. the brake will be triggered to close not later than after the waiting time has elapsed

even if the actual speed value is above the threshold for brake activation set in

C02581.

[9-11] Process of brake activation through time-out

Note!

In the Lenze setting the time monitoring function is not active (

C02593

= "0 s").



speed setpoint



actual speed value

n

C02581

: Brake activation threshold

o

C02593

: Waiting time for brake activation

r

The lapse of waiting time starts when

the speed setpoint has reached the

threshold for brake activation.

r

If the speed setpoint is still above the

threshold after the waiting time has

elapsed:
– The brake is automatically triggered

to close in automatic operation

(mode 2/12).

– The "brake activation via waiting

time" status is displayed at the

status output BRK_dnState via bit

23.

t

t

0

1

BRK_bReleaseBrakeOut

n



Œ

t

Standstill

t

Stopping

Advertising