9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00322

570

Firmware 1.37 - 09/2006

L

C00322

C00323

C00324

C00325

C00326

Parameter | Name:

C00322 | CAN TPDOx Tx mode

Data type: UNSIGNED_8

Index: 24253

d

= 5EBD

h

TPDO transmission mode according to DS301V402

• Types 0 (acyclic sync), 1-240 (cyclic sync), 254 (event-controlled manufacturer-specific), 255 (event-controlled

device-profile-specific) are supported.

• The basic PDO setting is "254" (event-controlled).
Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Information

C00322/1

254

Transmission mode for TPDO1 ... TPDO4

C00322/...
C00322/4

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00323 | CAN RPDOx Rx mode

Data type: UNSIGNED_8

Index: 24252

d

= 5EBC

h

RPDO transmission mode according to DS301V402

• With the RPDO used as monitoring setting for sync-controlled PDOs.

• Types 0 (acyclic sync), 1-240 (cyclic sync), 254 (event-controlled manufacturer-specific), 255 (event-controlled

device-profile-specific) are supported.

• The basic PDO setting is "254" (event-controlled).
Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Information

C00323/1

254

Transmission mode for RPDO1 ... RPDO4

C00323/...
C00323/4

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00324 | CAN TPDOx delay time

Data type: UNSIGNED_16

Index: 24251

d

= 5EBB

h

Minimum time between the sending of two identical TPDOs (see DS301V402).

• The delay time is entered in 1/10 ms and automatically rounded to full milliseconds by the code.
Setting range

(min. value | unit | max. value)

0

1/10 ms

65535

Subcodes

Lenze setting

Information

C00324/1

0 1/10 ms

Delay time for TPDO1 ... TPDO4

C00324/...
C00324/4

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00325 | Service code

Data type: UNSIGNED_8

Index: 24250

d

= 5EBA

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00326 | Service code

Data type: UNSIGNED_8

Index: 24249

d

= 5EB9

h

This code is used internally by the controller and must not be overwritten by the user!