9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

502

Firmware 1.37 - 09/2006

L

CAN module (MXI1): Invalid node address 0 [0x009d0001]

CAN module (MXI1): Basic configuration invalid [0x009d0002]

CAN module (MXI1): Heartbeat error index 1 [0x009e0000]

CAN module (MXI1): Heartbeat error index 2 [0x009e0001]

CAN module (MXI1): Heartbeat error index 3 [0x009e0002]

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked : Warning … Information

Cause

Remedy

CANopen communication module in MXI1: Initialisation

error

• The node address has been selected via DIP switch by

means of hardware and the DIP switches of the node

address are set to zero.

• Note: Instead of the impermissible node address 0 the

node address 1 is used.

• Use the DIP switches to set a node address unequal 0

and restart the controller.

• Activate the node number assignment by means of

software by changing the position of DIP switch 2 and

restart the controller.

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble : Warning locked … Warning … Information

Cause

Remedy

CANopen communication module in MXI1:

Configuration error

• Faulty download of an Engineer or PLC Designer

project

• Invalid CAN settings according to DS301V402 in the

Engineer or PLC Designer.

• Repeat download

• Correct CAN settings in the project and regenerate

project.

Response (Lenze setting printed in bold)

Setting:

C13613/1

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: Cyclic node

monitoring

• Node device has not received a heartbeat telegram

from node 1 within the defined time.

• Reactivate CAN node by restarting the controller,

restart of the controller (

C00002

="11000") or CAN

reset node.

• Select a different heartbeat producer monitoring

time or switch off monitoring and reset locked error

status, if necessary.

Tip: Safe the current parameter set before mains

switching and restarting the controller (

C00002

="11").

Response (Lenze setting printed in bold)

Setting:

C13613/2

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 2.

See remedy for "

Heartbeat error index 1

".

Response (Lenze setting printed in bold)

Setting:

C13613/3

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 3.

See remedy for "

Heartbeat error index 1

".