Plc configuration is invalid [0x00750006, Heatsink: temperature > c00122 [0x00770000, Heatsink: overtemperature [0x00770001 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 463: Motor: temperature > c00121 [0x00770002, Motor: overtemperature [0x00770003, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

463

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

PLC configuration is invalid [0x00750006]

Heatsink: Temperature > C00122 [0x00770000]

Heatsink: Overtemperature [0x00770001]

Motor: Temperature > C00121 [0x00770002]

Motor: Overtemperature [0x00770003]

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

An invalid control configuration has occurred.

Load other application.

Response (Lenze setting printed in bold)

Setting:

C00582

(; Adjustable response)

;

None … System fault ; Fault … Trouble … Quick stop by trouble … Warning locked : Warning … Information

Cause

Remedy

Heatsink temperature higher than variable limit

temperature (

C00122

).

• Controller ambient temperature too high.

• Dirty fan or ventilation slots.

• Value set under C00122 is too low.

• Check control cabinet temperature.

• Clean filter.

• Clean controller.

• Set a higher value under

C00122

.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Heatsink temperature higher than fixed limit

temperature (90 °C).

• Controller ambient temperature too high.

• Dirty fan or ventilation slots.

• Check control cabinet temperature.

• Clean filter.

• Clean controller.

Response (Lenze setting printed in bold)

Setting:

C00584

(; Adjustable response)

;

None … System fault ; Fault … Trouble … Quick stop by trouble … Warning locked : Warning … Information

Cause

Remedy

Motor temperature higher than variable limit

temperature (

C00121

).

• Motor too hot due to impermissibly high currents or

frequent and too long acceleration.

• No PTC connected.

• Value set under

C00121

is too low.

• Check drive dimensioning.

• Connect PTC or switch off monitoring (

C00584

="3").

• Set a higher value under

C00121

.

Response (Lenze setting printed in bold)

Setting:

C00583

(; Adjustable response)

;

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked ; Warning … Information

Cause

Remedy

Motor temperature higher than fixed limit temperature

(150 °C).

• Motor too hot due to impermissibly high currents or

frequent and too long acceleration.

• No PTC connected.

• Check drive dimensioning.

• Connect PTC or switch off monitoring (

C00584

="3").

Advertising